The Eddyfi PipeScan HD is a high-resolution magnetic flux leakage (MFL) corrosion mapping scanner designed for rapid inspection of ferrous piping, pressure vessels, tanks, and structural components. The system enables operators to quickly detect corrosion, pitting, and wall loss without couplant or extensive surface preparation. PipeScan HD uses high-density Hall-effect sensors and real-time C-scan imaging to provide immediate, traceable inspection results while permanently recording data for post-analysis and reporting. The scanner inspects through non-magnetic coatings up to 6 mm thick and supports multiple interchangeable heads for pipe diameters from 48 mm (1.9 in) through flat surfaces. PipeScan HD is compatible with Eddyfi Swift-M and Reddy-32M instruments and supports one-person operation at scanning speeds up to 1 m/sec.

Product Capabilities

  • High-resolution MFL corrosion mapping
  • Detection of corrosion and pitting in ferrous assets
  • Inspection through coatings and paint up to 6 mm thick
  • Detection capability down to 2 mm diameter defects
  • Real-time C-scan imaging
  • Permanent data recording and traceable reporting
  • One-person operation
  • Scanning speeds up to 1 m/sec (40 in/sec)
  • Pipe inspection from 48 mm (1.9 in) OD through flat surfaces
  • Compatible with Eddyfi Swift-M and Reddy-32M

Industries of Use

  • Oil & Gas – Pipeline, piping, and vessel corrosion assessment
  • Petrochemical – In-service process piping inspection
  • Refining – Corrosion screening in refinery piping systems
  • Power Generation – Boiler, service water, and condensate piping inspection
  • Chemical Processing – Inspection of coated ferrous pipe systems
  • Marine – Transfer line and terminal piping inspection
  • Utilities – Firewater and underground pipe integrity programs
  • Industrial Manufacturing – Preventive maintenance and asset integrity programs

Key Benefits

  • Reduces inspection time and labor requirements
  • Eliminates couplant and extensive surface preparation
  • Produces permanent, traceable inspection records
  • Improves probability of detecting corrosion and pitting
  • Enables immediate field decisions and reporting
  • Expands inspection coverage versus spot UT methods
  • Supports one-person operation
  • Reduces cost of large-scale integrity programs
Features:

Highest-Resolution MFL Imaging: PipeScan HD delivers high-definition magnetic flux leakage imaging with detailed C-scan maps for rapid corrosion and pitting identification.

Detects Small Defects: The system detects defects as small as 2 mm in diameter at 10% wall loss, improving early-stage corrosion detection.

Scans Through Coatings: PipeScan HD inspects through non-magnetic coatings and paint up to 6 mm (0.24 in) thick, reducing the need for coating removal.

No Couplant Required: The scanner requires no couplant and only minimal surface preparation, reducing setup time and simplifying field deployment.

Flexible Scanner Heads: Multiple interchangeable heads allow inspection of pipe diameters from 48 mm (1.9 in) through flat surfaces.

Permanent Data Recording: PipeScan HD records all inspection data, enabling adjustable reporting thresholds and immediate field report generation.

Applications:

Corrosion screening of ferrous process piping.

Pitting detection in carbon steel pipe systems.

Inspection of aboveground piping in refineries and petrochemical plants.

Corrosion mapping of tank-associated piping.

Inspection of vessel surfaces for corrosion and pitting.

Screening of coated ferrous piping with limited surface preparation.

Rapid in-service inspection programs where couplant-free testing is required.

Integrity assessment campaigns requiring recorded, auditable inspection data.

Inspection of small-diameter pipe using dedicated scanner heads.

Inspection of larger pipe diameters and flat ferrous surfaces.

Quantity must be 1 or more
Equipment available for both rental and purchase
Request a Quote

Specifications
Specification Details
Technology Magnetic Flux Leakage / Hall Effect Sensors
Method of Propulsion Hand Push
Scanning Speed Up to 1 m/sec (40 in/sec)
Model Options PS-HD-MFL-127XFLAT, PS-HD-MFL-73X127, PS-HD-MFL-48X6
OD Range 48 mm to flat (1.9 in to flat), depending on scanner head
OD Range by Head 127 mm to flat (5.0 in to flat), 73 mm to 127 mm (2.875 in to 5 in), 48 mm to 64 mm (1.9 in to 2.5 in)
Max Recommended Wall Thickness Up to 12.7 mm (0.5 in), depending on scanner head
Maximum Coating Thickness 6 mm (0.24 in) non-magnetic material
Number of Channels 27, 17, or 9 depending on scanner head
Channel Spacing 7 mm (0.27 in)
Smallest Detectable Defect 2 mm diameter defect at 10% wall loss
Maximum Surface Temperature 60°C (140°F)
Connecting Cable 5 m (15 ft) standard length
Weight 20.5 lb (9.3 kg)
Transit Case Meets IATA requirements for transporting magnetizable material
Compatible Instruments Swift-M, Reddy-32M
Profile Clearance 115 mm (4.5 in), 100 mm (4 in), or 100 mm (4 in) depending on scanner head
Maximum Width 317 mm (12.4 in), 242 mm (9.5 in), or 173 mm (6.8 in) depending on scanner head
Length 454 mm (17.8 in), 425 mm (16.7 in), or 409 mm (16.1 in) depending on scanner head